DocumentationBrowse this guide

Learn / Electronics

Kobee Studio: labels and typography

Build labels, symbols and title/subtitle artwork with containers, physical typography, independent ends and underlines.

DocumentationBeginner6 min8 Aug 2026KiCadPCB design
KiCad render of the Kobee Studio example board with labels, symbols and connector legends

Use Labels → Standard for text, symbols, and combined markings. The same live rendering workflow underlies connector and component tools, but Standard is the best place to learn shape and typography controls.

Start with the right content mode

  • Label — Text without an accompanying symbol
  • Label + symbol — A warning, interface name, power rail or other combined marking
  • Symbol only — A standalone electrical, polarity or control icon

Type directly into Label text, or choose Quick label to start with a common term. Quick labels are editable content presets; profiles save the wider tool settings. You can build your own quick-label library in Settings → Asset library.

Create a label step by step

  1. Open Labels → Standard → Basics and choose Label.
  2. Enter a short, concrete name such as RESET, USB or 3V3.
  3. Open Typography. Choose a typeface and main text height.
  4. Open Container. Choose a shape and appearance, then adjust border and padding.
  5. Select the intended target layers and inspect each preview.
  6. Place the artwork. Check its real size beside the hardware in PCB Editor.
  7. Reopen the placed item to verify its saved settings before repeating the style across the board.

Shapes, appearance and spacing

The shape library includes rounded rectangles, pills, flags, tabs, pointers, chamfers and hexagonal forms. Some controls apply only to certain shapes; changing the shape can hide an irrelevant setting.

Appearance determines how the geometry reads. An outline leaves the inner region open and draws a border. Inverted artwork uses text/symbol cut-outs in a filled region. Bare/container-free layouts keep the content without a surrounding enclosure.

Padding creates room between content and its container. Increase left/right padding for a less cramped name; increase top/bottom padding when letters or symbols approach the enclosure. Padding is separate from border thickness and from the gap between a symbol and text.

Corner radius changes the roundness of compatible corners. A large radius cannot make every small shape visually identical: inspect the resulting geometry at the intended dimensions.

Independent ends lets you give the two ends different treatments, including Square, Rounded, Chamfered, Point and Notch. Use this for direction or grouping, such as a pointed signal label and a square connector-facing end. Compare the preview after changing direction; do not assume the screen's left end always corresponds to your final board orientation.

Physical typography

Text height is a board dimension. Choose it for the space and manufacturing process, not for how large the zoomed preview looks. Different fonts produce different stroke weights, counters and word widths at the same height.

Use line spacing and alignment controls to arrange multiple lines within the label. If a word becomes too wide, consider shortening it, selecting a narrower face before making the entire label too small to fabricate.

The special-character controls include forward slash and backslash for interface or path names. Verify that a chosen typeface contains any special glyph you use; an unsupported glyph cannot be fixed with extra padding.

Add a symbol

  1. Choose Make → Label + symbol.
  2. Open the symbol picker and search or browse for the mark you need.
  3. Select the symbol and, where provided, its variant.
  4. Choose a supported symbol/text layout and adjust symbol height and gap.
  5. Inspect the content as one unit: symbol weight, text height and container margins should work together.

For a standalone mark, choose Symbol only. A built-in electrical symbol and a custom uploaded SVG use the same picker workflow. See SVG authoring for import and compatibility guidance.

Title and subtitle

Use Text layout → Title + subtitle when a short primary name needs a supporting line, such as POWER above 5–12 V DC.

  1. Enter the primary title and the subtitle in the exposed content fields.
  2. Choose main and subtitle heights, then adjust their gap.
  3. Start with the subtitle following the main typeface. Use the advanced subtitle typeface override only when you need a different face.
  4. Check alignment and padding with both the longest title and the longest subtitle you expect to use.

A subtitle is a second line of artwork, not electrical schematic data. Changing it does not change net names or component values.

Underline main text

Enable Underline main text for a stronger label hierarchy. The tool exports an actual geometry underline that works with bare, outline and inverted labels. Advanced controls adjust underline thickness and the gap below the letters.

Increase the bottom padding if the underline gets too close to the container. At small sizes, inspect the separation between descenders, underline and border. The 1.5 editor also has independent overlines and opt-in scoped text formatting; see formatting and variables.

Legacy inline markup

In the 1.5 Advanced section, use Text formatting → Enable for explicit subscript, superscript, overline and underline notation. With formatting disabled, the characters stay literal. For example, use D_{0} for a subscript group or V^{2} for a superscript group. Use the formatting reference for the supported notation. Do not look for the older 1.4 Legacy inline markup controls in this new editor.

Worked example: a reset warning

Create RESET with a suitable control symbol, use an outline container, choose a 1.2 mm main text height as a starting point, then tune the icon height until its visual weight matches the text. Leave enough gap that the icon and R do not merge. Place it on front silk near the reset control, outside the component envelope.

For consistent copies, save a profile. For an enclosure that follows a real switch's body dimensions, use Component Callout instead.

When the result needs adjustment

  • The lettering fills in: increase text size, use a less dense typeface or simplify the appearance. Check actual feature widths.
  • The border touches the content: adjust the appropriate padding, then check underline and symbol gaps separately.
  • A symbol disappears: confirm the content mode includes a symbol and that the selected asset is available.
  • A changed label produces a new footprint: select one existing Kobee item before reopening; see editing.